

i sell the item as it shows in the picture.i will not re-ship any free parts of the watch after been shipped. Resolution is 0.1 milliseconds the measuring range is 0-9.9 ms.- Lift Angle: the measuring range is 30 ° to 70 °, the factory set it to 52 °.- Supply voltage: single-phase AC 100 Vï½ 240V ± 10% two-line.- Measure positions: 1 to 6 positions.- Use of the environment: 0 â to 50 â, relative humidity:0 to 80% RH- Shell: Light grey plastic- Dimensions: 173à 9.5à 11.5mm- Weight: 402gcontent:1 equipment2 power plug 3 sensor4 manual-Repair:one year international warranty, buyer pay returning shipping cost.-returns:Due to this is a very precison machine, we dont not accept any returns! Pls read below info before you buy it.1)we offer tracking nbrs,but usaually it will take 4-5 days toshows on the post office system.shipping time listed below.2)pls check the pictures clearly. The lift angle can be set to between 30°and 70°PeriodThe measuring period selectable:2sã 4sã 8sã 10sã 20sã 30sã 60sUse to recalculate the average values of the test result.Specifications:- Measuring possibilities: Rate deviation, amplitude, beat error of mechanical watches and diagram recording of the beat noise.- Frequency numbers: It can selected out the common beat number automaticly, also can selected out the less common beat number by manual.- Rate deviation measurement: the range of deviation is ± 999 sec / day, precision 1.0 sec/day.- Amplitude measurement: Numerical display in degrees, resolution is 1°,measuring range: 100°to 360° (the lift angle can affect the amplitude, range: 30°to 70°.Under normal circumstances, the amplitude value do not exceed 360°.)- Measuring period times for the average numerical results: 2s, 4s, 8s, 10s, 20s, 30s, 30s, 60s.- Measuring of the Beat error(Frequency error): Numerical display in milliseconds. This value is required to calculate the amplitude and must be selected according to the watch movement. 1000 is a precise mechanical watches test instrument, it is used for multi-testing by watch manufacturers and watch technician.- The frequency diagram of the watch can be displayed in the LCD screen.- According to different watches, the instrument will automatically adjust optimal signal level during testing.- The instrument will automatically calculate the rate, amplitude, beat error, and display them by data in real time.- For the conventional beat, the instrument can automatically response for the special beat, can manually select.- The sampling period can selected by 2 seconds, 4 seconds, 6 seconds, 8 seconds, 10 seconds, 20 seconds, 30 seconds, 60 seconds, and the average of corresponding period will be regard as the precise value of the watch.- Six kinds of testing position can be adjusted, and the simulation sound can be play in the speaker or muteBeat Numbers (Frequency Numbers)AutomaticThe following beat numbers are selected by automatic selection mode:12000ã 14400ã 18000ã 19800ã 21600ã 25200ã 28800ã 36000ã 43200(If the tested beat is not in automatically selection, the instrument will display the closest beat number, but the test result is not correct. Description: Multifunction Timegrapher NO.1000 Watch Timing Machine Calibration ToolsFeatures:- The NTimegrapher NO.

WATCH TIMEGRAPHER REPLACEMENT MICROPHONE PROFESSIONAL
Item: 182102353591 Timegrapher NO.1000 Watch Timing Machine Multifunction Tester Professional RCMD.
